Novosafe CP-S

Halogen free shielded (EMC) motor cable for drag chains 0,6/1 kV
  • 4 (11)
  • Yes (11)
  • 70 (1)
  • 95 (1)
E-numberDimension n x mm²Manufacturer specOuter diameter mmWeight kg/100m
02694204G1,56FX8008-1BB119.216
02694304G2,56FX8008-1BB2110.624
02694404G46FX8008-1BB3111.931
02694504G66FX8008-1BB4114.743
02694604G106FX8008-1BB5117.563
02694704G166FX8008-1BB6121.695
02694804G256FX8008-1BB2525.2160
02694904G356FX8008-1BB3528.7200
02695004G506FX8008-1BB5033.4256.8
N75886404G706FX8008-1BB7040.5378
4G956FX8008-1BB9547.5520
Standard:
VDE 0207, 0250, 0293, 0295, 0472, IEC 60228 cl. 6
Approvals:
Complies to Swedish and European standard acc. to SS EN 60204 and UL/CSA
Rated Voltage Uo/U:
0,6/1kV
Rated Voltage acc to. UL/CSA:
1000V
Conductor class:
Class 6 = extra fine stranded wires
Conductor material:
Copper
Core insulation:
Polypropylene (PP)
Core identification:
Black with white printing ( U/L1/C/L+, V/L2, W/L3/D/L-) + GREEN-YELLOW.
Protective conductor:
Yellow/Green
Overall shield:
Braided tinned copper wire
Shield coverage:
Approx. 85%
Outer sheath:
PUR
Sheat colour:
Orange RAL 2003
Bending radius fixed:
3 x outerdiameter ≤ 16mm², 5 x outerdiameter ≥25mm²
Bending radius moved:
6 x outerdiameter ≤ 16mm², 10 x outerdiameter ≥25mm²
Min operating temperature fixed:
-40°C
Max operating temperature fixed:
+90°C
Min operating temperature moved:
-30°C
Max operating temperature moved:
+90°C
Testing voltage:
4000V
Oil resistance:
EN 50363-10-2, UL 1581
UV resistant acc. to:
EN 50289-4-17, ASTM-D-2565-16, ISO 4892-2
Ozone resistans acc:
EN 50396 art. 8.1.3
Halogen-free acc. to:
IEC 60754
Flame retardant:
IEC 60332-1, UL1581 VW1, CSA FT1